Power Control within Serial Session

Power Control within Serial Session

Nodegrid Serial Console features the Power Control integration which gives authorized users the ability to power on, power off and reset/reboot the serial devices, within the serial session, by using an escape character (default escape character is Ctrl-O).

Follow the steps below to configure the Power Control for the serial port.

  • Add a Switched Power Strip from the network
    1. Go to Managed Devices and click on Add button.
    2. Enter a name, select the PDU type, IP Address and username/password of the Power Strip.
    3. Click on Save
  • Scroll down the Devices page, and click on the Power Strip name just added
    1. Click on Management tab
    2. Enable SNMP and Version, and enter the ReadWrite community (check Power Strip’s SNMP settings)
    3. Click on Save
    4. Click on Commands tab, and click on Outlet command
    5. Check Enabled checkbox, set Protocol to SNMP and save.
    6. Click on Outlets Tab and confirm the outlets are listed
  • Click on Devices, and click on the serial port name you want to integrate power outlet(s)
    1. Click on Commands tab and click on Outlet command
    2. Check Enabled checkbox
    3. Select the outlet(s) and click on Add button
    4. Click on Save
    5. Repeat these steps for other serial ports and outlets.

 

Test the Power Management integration

Once you establish a telnet or ssh session to a serial port, hit CTRL O to call the Power Control menu.

It should present the following options:

Power Menu - <Device_Name>

Options:

  1. Exit
  2. Status
  3. On
  4. Off
  5. Cycle

Please choose an option:

Select the option 3 to turn the outlet On, 4 to turn the outlet Off, 5 to power cycle, 2 to check the outlet state (whether On or Off), 1to exit from the Power Menu, and get back to the serial session

Note: Power hot key sequence is a configurable parameter and can be defined individually for each device. The power menu option can be customized under the Managed Devices::Preferences 


    • Related Articles

    • How to Configure Nodegrid Serial Ports

      To configure the serial ports of your Nodegrid Serial Console, follow the guideline steps below.   WebUI Log in as admin to the Nodegrid Serial Console Web interface. Go to Managed Devices page. Select the serial ports you want to configure, or check ...
    • Nodegrid Serial Console: Pinouts, Cables and Connectors

      The tables below show the serial port pinout information of the NSC TxxR (Cisco Pinout) and NSC Txx (Legacy Pinout). NSC TxxR - Cisco-like Pinout Pin Signal Name Input/Output 1 CTS IN 2 DCD IN 3 RxD IN 4 GND N/A 5 GND N/A 6 TxD OUT 7 DTR OUT 8 RTS ...
    • How to Telnet and SSH to the Nodegrid Serial Ports

      Note: by default, Telnet access is turned off with your Nodegrid Serial Console. Authorized users can use Telnet or SSH to connect directly to the console of a managed device if all of the following are true: Telnet / SSH protocol is enabled under ...
    • What is the NodeGrid Serial Console Power specification?

      The NodeGrid Serial Console has the following power specs: Single or Dual AC: 100–240 VAC, 50/60 Hz @ 0.9A max with no more than 45W of Power consumption.
    • Can I Cascade NodeGrid Serial Console Units?

      NodeGrid Serial Console (NSC) serial console server is able to share network ports with fellow devices, sharply reducing network switch port usage for OOB device management. This new port saving feature is already reliably and securely saving many ...