Distance limit for serial cable over copper cat6
Nodegrid appliances' serial ports support the following cable length per baud rate with CAT6 cable:
Serial port at 115200bps passed at 500ft (152.4m)
Serial port at 9600bps passed at 1200ft (365.8m)
Related Articles
Nodegrid Serial Console: Pinouts, Cables and Connectors
The tables below show the serial port pinout information of the NSC TxxR (Cisco Pinout) and NSC Txx (Legacy Pinout). NSC TxxR - Cisco-like Pinout Pin Signal Name Input/Output 1 CTS IN 2 DCD IN 3 RxD IN 4 GND N/A 5 GND N/A 6 TxD OUT 7 DTR OUT 8 RTS ...
Devices Pinout with Nodegrid serial port
The table below shows the configuration of the cable or adapter that you can make as the target device that you are connecting to Nodegrid serial ports (Cisco pinout) has proprietary pinout on their console port. 1. Nodegrid - Dell EqualLogic Pinout ...
Rename an attached serial port
Rename an attached serial port via Web Interface Prior to 5.10.x, to rename an attached serial port, you need to go to Managed Devices :: Devices, tick the serial port that you want to rename and click on "Rename": Then change the name and "Save": ...
Power Control within Serial Session
Nodegrid Serial Console features the Power Control integration which gives authorized users the ability to power on, power off and reset/reboot the serial devices, within the serial session, by using an escape character (default escape character is ...
How to Configure Nodegrid Serial Ports
To configure the serial ports of your Nodegrid Serial Console, follow the guideline steps below. WebUI Log in as admin to the Nodegrid Serial Console Web interface. Go to Managed Devices page. Select the serial ports you want to configure, or check ...